Additional kit „Inverse“

Application

  • Cutting edge of the tool > tool shank diameter
  • Suitable for inverse shrinking up to machine interface HSK-A63
  • Induction coil only possible in combination with the quick change coil technology (...WS...)
  • Induction coil also suitable for the earlier models of the ISG3200 series

 

Shrink process:
Example ISG3410WK-WS with inverse kit ISGZ 3400WK-INV

1. Insert the tool holder extension together with HSK-A63 tool adaptors
2. Position the shrink chuck as shown in Image 1
3. Plug in the inverse coil
4. Position the stop block shown in Image 2 (top shrink chuck = top inverse coil )
5. Select „inverse shrinking“ in the menu

Suitable for the following machines

Contacts